Answer checking requires JavaScript. You can still read the lesson, figures, and questions.
Skip to lessonDDQX Learning Institute
Atomic Structure, Decay, and Quantized Light
Keep particle inventories, electron configurations, decay measurements, and photon energy distinct.
What You Will Be Able to Do
- Conserve nucleon and electric charge across nuclear changes, including electron capture.
- Infer electron configuration, unpaired electrons, and periodic trends from specified atomic states.
- Read a decay time course after background correction and distinguish activity from absorbed dose.
- Use photon energy, work function, and stopping voltage without conflating intensity with photon energy.
Orient
Conserve Three Different Inventories
An isotope specifies atomic number Z (protons) and mass number A (protons + neutrons). N = A − Z. An atomic ion has Z − positive charge electrons; electrons do not change the isotope’s mass number. For nuclear electron capture, a proton captures an inner electron, forming a neutron and an electron neutrino, so A is unchanged and Z decreases by one. This differs from removing an orbital electron when making a chemical ion.
The live Atomic Identity and Nuclear Change lesson already covers electron capture. It is retained, not duplicated as a rewrite.
Need a hint?
Keep A, Z, and charge as separate columns.
Need a hint?
Track nucleon count separately from proton count.
Worked
Specify the State Before Counting Unpaired Electrons
For a neutral ground-state Fe atom (Z=26), a convenient shorthand is [Ar] 3d⁶ 4s². Forming Fe³⁺ removes the 4s electrons before one 3d electron, yielding [Ar] 3d⁵, with five unpaired electrons in an isolated high-spin free-ion orbital-counting model. Chemical bonding and ligands can alter spin states: do not assume that result describes every Fe-containing complex.
In a sequence of ionization energies, a large jump after removing two electrons suggests two accessible valence electrons under the stated elemental model. Electron Configurations and Periodic Trends already teach the core counting and trend relationships.
Need a hint?
Remove 4s electrons first, then fill five d orbitals singly.
Need a hint?
Locate the position of the largest jump, not the largest numerical value alone.
Worked
Subtract Detector Background Before Fitting Decay
Original synthetic decay teaching dataset. A detector counts events per minute (counts/min); it has separately measured, assumed constant background 20 counts/min. The sample’s ideal background-corrected model starts at 800 counts/min and halves every 3.0 h. The complete observed time course—not just endpoints—is supplied below. Count rates are not automatically biological absorbed dose or a calibrated source activity in Bq; detector efficiency and geometry are not specified.
| Elapsed time (h) | Observed (counts/min) | Background (counts/min) | Net sample signal (counts/min) |
|---|---|---|---|
| 0 | 820 | 20 | 800 |
| 3 | 420 | 20 | 400 |
| 6 | 220 | 20 | 200 |
| 9 | 120 | 20 | 100 |
| 12 | 70 | 20 | 50 |
Under the assumed exponential model, N(t) = N₀·2^(−t/t½) and the log of net signal changes linearly with time. Background must be subtracted before taking the logarithm. A log plot made from total counts would flatten as the net signal approaches the background.
Review radioactive decay and semilog data.
Need a hint?
Subtract background first, then compare two net signals.
Guided
Separate Activity, Absorption, and Biological Weighting
Activity is nuclear decays per second, measured in becquerels (Bq). Absorbed dose is energy deposited per mass, measured in grays (Gy = J/kg). Equivalent dose additionally weights radiation type and is expressed in sieverts (Sv). Counts/min recorded by a detector depend on efficiency, geometry, and background, so an observed count rate is not automatically source activity, absorbed dose, or a clinical risk estimate. No patient protection, treatment, or exposure recommendation is implied.
This distinction is the bounded 4E radiation gap. It is supplied here as a formative comparison, not as a new recommendation for radiation practice.
Need a hint?
Write the units of absorbed dose before selecting required quantities.
Guided
Let Stopping Voltage Measure Maximum Photoelectron Energy
A photon with Eγ = hf can eject a photoelectron only if Eγ exceeds a specified work function φ. In the simplest one-photon model, Kmax = hf − φ = e·Vstop, where Vstop is the magnitude of the retarding potential needed to stop the fastest electrons. When energies are expressed in electronvolts, the numerical stopping voltage in volts equals Kmax in eV.
Synthetic model: At λ = 400 nm, Eγ ≈ 1240 eV·nm / 400 nm = 3.10 eV. If φ = 2.00 eV, then Kmax = 1.10 eV and Vstop = 1.10 V. More above-threshold photons per second can raise emitted current under the stated model, but do not by themselves raise Kmax or Vstop.
The live Atomic Spectra and the Photoelectric Effect lesson now includes stopping voltage. This additional case tests changed conditions rather than asking for a duplicate explanation.
Need a hint?
Photoelectrons spend φ before any kinetic energy remains.
Independent Transfer
Reconcile the Models Instead of Memorizing Results
Work from isotope inventories through signal corrections and quantized energy. A numeric answer alone is insufficient if the variable or unit is mislabeled; select the competitor that reflects the stated measurement.
Need a hint?
A and Z define the nucleus; charge adjusts electrons only.
Need a hint?
Read the transition between successive IE values, not the row length.
Need a hint?
Compute the number of half-lives from elapsed time divided by t½.
Delayed Retrieval
Return After a Delay
Before revisiting explanations, write the effect of electron capture on A and Z, why 20 counts/min of background changes a decay fit, and why a brighter fixed-color beam does not necessarily have a higher stopping potential.
Need a hint?
Distinguish how many photons arrive from the energy of each photon.

