Atomic Structure, Decay, and Quantized Light

Answer checking requires JavaScript. You can still read the lesson, figures, and questions.

DDQX Learning Institute

Atomic Structure, Decay, and Quantized Light

Keep particle inventories, electron configurations, decay measurements, and photon energy distinct.

42 min guided route11 uncalibrated formative activitiesOriginal formative practice
For practice, not score prediction. These activities are original guided/transfer exercises, not official MCAT items or independent validated passages. Existing DDQX lessons and attempts remain unchanged.

What You Will Be Able to Do

  • Conserve nucleon and electric charge across nuclear changes, including electron capture.
  • Infer electron configuration, unpaired electrons, and periodic trends from specified atomic states.
  • Read a decay time course after background correction and distinguish activity from absorbed dose.
  • Use photon energy, work function, and stopping voltage without conflating intensity with photon energy.

Orient

Conserve Three Different Inventories

An isotope specifies atomic number Z (protons) and mass number A (protons + neutrons). N = A − Z. An atomic ion has Z − positive charge electrons; electrons do not change the isotope’s mass number. For nuclear electron capture, a proton captures an inner electron, forming a neutron and an electron neutrino, so A is unchanged and Z decreases by one. This differs from removing an orbital electron when making a chemical ion.

The live Atomic Identity and Nuclear Change lesson already covers electron capture. It is retained, not duplicated as a rewrite.

Guided • M10-G1
A magnesium-25 ion has atomic number 12 and a 2+ charge. How many neutrons and electrons does it contain?
Need a hint?

Keep A, Z, and charge as separate columns.

Guided • M10-G2
A sodium-22 nucleus (Z=11) undergoes electron capture. Which daughter nucleus results immediately after the nuclear transformation?
Need a hint?

Track nucleon count separately from proton count.

Worked

Specify the State Before Counting Unpaired Electrons

For a neutral ground-state Fe atom (Z=26), a convenient shorthand is [Ar] 3d⁶ 4s². Forming Fe³⁺ removes the 4s electrons before one 3d electron, yielding [Ar] 3d⁵, with five unpaired electrons in an isolated high-spin free-ion orbital-counting model. Chemical bonding and ligands can alter spin states: do not assume that result describes every Fe-containing complex.

In a sequence of ionization energies, a large jump after removing two electrons suggests two accessible valence electrons under the stated elemental model. Electron Configurations and Periodic Trends already teach the core counting and trend relationships.

Guided • M10-G3
In a simple isolated high-spin Fe³⁺ free-ion electron-counting model, how many unpaired 3d electrons are present?
Need a hint?

Remove 4s electrons first, then fill five d orbitals singly.

Guided • M10-G4
A neutral main-group atom shows successive ionization energies of 600, 1250, and 7600 kJ/mol. Which valence-electron count is most strongly suggested?
Need a hint?

Locate the position of the largest jump, not the largest numerical value alone.

Worked

Subtract Detector Background Before Fitting Decay

Original synthetic decay teaching dataset. A detector counts events per minute (counts/min); it has separately measured, assumed constant background 20 counts/min. The sample’s ideal background-corrected model starts at 800 counts/min and halves every 3.0 h. The complete observed time course—not just endpoints—is supplied below. Count rates are not automatically biological absorbed dose or a calibrated source activity in Bq; detector efficiency and geometry are not specified.

Elapsed time (h)Observed (counts/min)Background (counts/min)Net sample signal (counts/min)
082020800
342020400
622020200
912020100
12702050

Under the assumed exponential model, N(t) = N₀·2^(−t/t½) and the log of net signal changes linearly with time. Background must be subtracted before taking the logarithm. A log plot made from total counts would flatten as the net signal approaches the background.

Review radioactive decay and semilog data.

Synthetic Detector Counts Across Time on a Logarithmic Vertical ScaleObserved counts per minute are 820, 420, 220, 120, and 70 at 0, 3, 6, 9, and 12 hours. Subtracting 20 background counts per minute yields 800, 400, 200, 100, and 50, respectively. Both series decline; the net series halves every 3 hours and is a straight line on the logarithmic axis.Synthetic count-rate model; log₂ vertical scale50100200400800036912Elapsed time (h)Counts/min (log scale)RecordedNet
Original synthetic instructional data, not an adapted published study
Guided • M10-G5
In the supplied synthetic decay dataset, the recorded 9-hour count rate is 120 counts/min and constant background is 20 counts/min. What fraction of the original 800-counts/min net sample signal remains?
Need a hint?

Subtract background first, then compare two net signals.

Guided

Separate Activity, Absorption, and Biological Weighting

Activity is nuclear decays per second, measured in becquerels (Bq). Absorbed dose is energy deposited per mass, measured in grays (Gy = J/kg). Equivalent dose additionally weights radiation type and is expressed in sieverts (Sv). Counts/min recorded by a detector depend on efficiency, geometry, and background, so an observed count rate is not automatically source activity, absorbed dose, or a clinical risk estimate. No patient protection, treatment, or exposure recommendation is implied.

This distinction is the bounded 4E radiation gap. It is supplied here as a formative comparison, not as a new recommendation for radiation practice.

Guided • M10-G7
What additional information is indispensable for converting a detector count rate into absorbed dose to a specific tissue?
Need a hint?

Write the units of absorbed dose before selecting required quantities.

Guided

Let Stopping Voltage Measure Maximum Photoelectron Energy

A photon with Eγ = hf can eject a photoelectron only if Eγ exceeds a specified work function φ. In the simplest one-photon model, Kmax = hf − φ = e·Vstop, where Vstop is the magnitude of the retarding potential needed to stop the fastest electrons. When energies are expressed in electronvolts, the numerical stopping voltage in volts equals Kmax in eV.

Synthetic model: At λ = 400 nm, Eγ ≈ 1240 eV·nm / 400 nm = 3.10 eV. If φ = 2.00 eV, then Kmax = 1.10 eV and Vstop = 1.10 V. More above-threshold photons per second can raise emitted current under the stated model, but do not by themselves raise Kmax or Vstop.

The live Atomic Spectra and the Photoelectric Effect lesson now includes stopping voltage. This additional case tests changed conditions rather than asking for a duplicate explanation.

Guided • M10-G6
A 400-nm photon has energy 3.10 eV and a metal work function is 2.00 eV. Under the single-photon photoelectric model, what is the stopping-potential magnitude?
Need a hint?

Photoelectrons spend φ before any kinetic energy remains.

Independent Transfer

Reconcile the Models Instead of Memorizing Results

Work from isotope inventories through signal corrections and quantized energy. A numeric answer alone is insufficient if the variable or unit is mislabeled; select the competitor that reflects the stated measurement.

Transfer • M10-T1
A neutral chlorine-37 atom (Z=17) gains one electron to form a 1− ion. How many neutrons and electrons does the ion have?
Need a hint?

A and Z define the nucleus; charge adjusts electrons only.

Transfer • M10-T2
A neutral main-group atom has successive ionization energies of 720, 1450, 7700, and 10500 kJ/mol. Which model fits the large early jump?
Need a hint?

Read the transition between successive IE values, not the row length.

Transfer • M10-T3
A different isotope has half-life 2.0 h and initial background-corrected detector signal 800 counts/min. What net signal is expected after 6.0 h under the same exponential model?
Need a hint?

Compute the number of half-lives from elapsed time divided by t½.

Delayed Retrieval

Return After a Delay

Before revisiting explanations, write the effect of electron capture on A and Z, why 20 counts/min of background changes a decay fit, and why a brighter fixed-color beam does not necessarily have a higher stopping potential.

Retrieval • M10-D1
An experiment doubles the intensity of above-threshold monochromatic light, preserving frequency and work function. Under a simple photoelectric model, what happens to stopping voltage?
Need a hint?

Distinguish how many photons arrive from the energy of each photon.