Answer checking requires JavaScript. You can still read the lesson, figures, and questions.
DDQX Learning Institute · MCAT 4C · Learning Thread P04
From Electric Fields to Membrane Voltage
Keep the source, the circuit, and the membrane model separate. Connect them only after you identify what each measurement means.
What You Will Do
Determine the field direction and signed force for a two-source configuration; distinguish emf from terminal voltage; carry a current and capacitance account without switching boundary conditions; and test a simple membrane-charging model against measured pulse data.
1. Source Charge Is Not Test-Charge Force
At the midpoint between equal and opposite point-source charges, the field from the positive charge points away from it, and the field from the negative charge points toward it. Both contributions point toward the negative source. A negative test charge experiences force opposite that field. For point-source magnitudes, use E = k|Q|/r2, add vectors, and only then apply F = qE. Potentials, by contrast, add as signed scalars.
Worked Comparison
Two sources of +2.0 nC and −2.0 nC sit 0.40 m apart. At their midpoint, each source is 0.20 m away, and each contributes 450 N/C to the right. The net field is 900 N/C right. A −1.0 nC test charge experiences 9.0 × 10−7 N left. The signed electric potential at the midpoint is zero under the same infinity reference, even though the field is not zero.
Guided Check · P04-Q1
Repair the Model
Draw the field from each source independently at the observation point. Add vectors first. Only afterward use the sign of the movable test charge.
Fresh Transfer Case
2. A Battery Can Supply an Emf Without Delivering That Voltage to Its Load
Consider an illustrative source with emf 12.0 V and internal resistance 1.0 Ω. Its external load is a 2.0 Ω resistor in series with a 6.0 Ω and 3.0 Ω parallel pair. Reduce the pair first: (6 × 3)/(6 + 3) = 2.0 Ω. The external resistance is 4.0 Ω, and the complete series resistance, including the source interior, is 5.0 Ω.
| Quantity | Value and reasoning |
|---|---|
| Source current | 12.0 V / 5.0 Ω = 2.40 A |
| Terminal voltage | 12.0 V − (2.40 A × 1.0 Ω) = 9.60 V |
| Drop across first 2.0 Ω | 2.40 A × 2.0 Ω = 4.80 V |
| Drop across each parallel branch | 4.80 V |
| Branch currents | 0.80 A through 6.0 Ω; 1.60 A through 3.0 Ω |
The two branch currents sum to 2.40 A. A voltmeter across the terminals reads 9.60 V under load, not 12.0 V, because the internal resistance dissipates power. Conventional current is not a claim that electrons in the metal move in the same direction.
Guided Check · P04-Q2
Repair the Model
Reduce the parallel network, add its series resistor, then add the source internal resistance. Only the resulting current can tell you the load voltage.
Fresh Transfer Case
3. Charge Separation and Ionic Equilibrium Are Different Models
For a capacitor, Q = CΔV and U = ½C(ΔV)2. A membrane’s lipid bilayer can store separated charge, while selective ion channels determine currents and the concentrations determine electrochemical gradients. A capacitor calculation does not determine a Nernst potential or replace the Goldman–Hodgkin–Katz permeability model. Do not use channel conductance as though it were a Goldman permeability without an independently justified conversion.
Worked Model: A Brief Injected Pulse
A patch of membrane is modeled as a 1.0 nF capacitor at −70 mV (inside relative to outside). For a brief interval, leakage and gating changes are assumed negligible. A net inward positive current of 2.0 nA lasts 5.0 ms. Thus ΔQ = IΔt = 10 pC, and ΔV = ΔQ/C = +10 mV. The predicted new voltage is −60 mV. This is a stated ideal capacitor approximation, not a general prediction of an actual neuron’s action potential.
Guided Experiment: Change Pulse Duration, Not Capacitance
The following dataset is synthetic and explicitly idealized for teaching, not a published experiment. A current-injection circuit supplies measured net inward current, and a voltage sensor measures the inside-minus-outside membrane potential after each pulse. The capacitance (1.0 nF) was calibrated independently with a small test pulse. Each trial begins at −70 mV; other conditions, including the assumed negligible leakage, are held constant. A zero-current trial is the control.
| Trial | Current (nA) | Pulse (ms) | Measured end Vm (mV) |
|---|---|---|---|
| Control | 0 | 5 | −70 |
| A | 2.0 | 5 | −60 |
| B | 2.0 | 10 | −50 |
What changes across trials is the total net injected charge; the measured output is membrane voltage. The doubled time of trial B doubles the ideal ΔV at fixed current and capacitance. If appreciable leak currents occur, this linear prediction can fail, and the model must be expanded rather than quietly reinterpreting the measured current as the ideal charging current.
Guided Check · P04-Q3
Repair the Model
Keep separate: measured net injected current, duration, independently calibrated capacitance, and observed end voltage. These data do not reveal individual ion permeabilities.
Fresh Transfer Case
Independent Check · P04-Q4
Repair the Model
Write a charge balance: CΔVm = ∫(Iinjected − Iionic)dt. The synthetic ideal model set Iionic ≈ 0; if reality differs, measure the missing term rather than substitute an unrelated parameter.
Fresh Transfer Case
Return to This Thread
Optional Delayed Retrieval: Reconstruct Without Your Notes
Describe one situation in which electric potential is zero but electric field is not. Explain why 12 V emf does not guarantee 12 V across a load. State which assumption allows a constant current to produce a linear ΔV across membrane capacitance. After answering aloud, reopen the relevant original lesson if any step fails.
Next: Connect electrochemical potential to electron transfer in Redox Half-Cells to Electrolysis. The inter-unit link is a binding token for FINAL; no current public URL is implied.

