Answer checking requires JavaScript. You can still read the lesson, figures, and questions.
DDQX Learning Institute · MCAT 4C and 5A · Learning Thread P05
From Electron Bookkeeping to Measured Electrolysis
Carry the same electron account through balanced half-reactions, cell direction, concentration effects, and actual deposited mass.
What You Will Do
Prove a balanced redox stoichiometry before using titration data, assign anode and cathode using half-reactions rather than memorized signs, infer the polarity of a concentration cell, and determine the theoretical and observed products of a controlled electrolysis experiment.
1. The Half-Reaction Account Sets the Mole Ratio
In acidic solution, a specified dichromate/iodide oxidation-reduction reaction is Cr2O72− + 14H+ + 6I− → 2Cr3+ + 3I2 + 7H2O. Two chromium atoms each accept three electrons, and six iodide ions collectively supply six electrons. Both sides have total charge +6. These conservation checks precede all volume or endpoint arithmetic.
Worked Endpoint Transfer
Assume the named reaction is quantitatively complete and selective at a validated endpoint in acidic medium. A 20.0 mL iodide aliquot needs 10.0 mL of 0.0100 M dichromate solution. The 1.00 × 10−4 mol dichromate corresponds to 6.00 × 10−4 mol iodide. Dividing by 0.0200 L gives [I−] = 0.0300 M. This is a synthetic stoichiometric teaching example, not an experimental source claim.
Guided Check · P05-Q1
Repair the Model
Check all atoms, charge, and electrons. Use n(analyte) = reaction coefficient ratio × n(titrant); only then divide by the analyte aliquot volume.
Fresh Transfer Case
2. Reduction Potential Does Not Multiply With Half-Reaction Coefficients
For two hypothetical reversible half-cells at standard conditions, M2+ + 2e− → M has E°red = +0.34 V and X2+ + 2e− → X has E°red = −0.76 V. M reduction occurs at the cathode; X metal oxidizes at the anode. E°cell = +0.34 − (−0.76) = +1.10 V. Doubling a half-reaction’s coefficients to cancel electrons does not double its intensive electrode potential. Electrons travel through the external conductor, while ions in the electrolyte/salt bridge maintain charge balance.
Guided Check · P05-Q2
Repair the Model
Label both half-reactions as reductions first. Choose the cathode by more positive Ered, reverse the other for oxidation, and subtract cathode minus anode reduction potentials.
Fresh Transfer Case
Changed Case: A Concentration Cell
Now both electrodes are the same metal, at 25 °C, and ideal dilute-solution activities are approximated by molar concentrations. The M2+ concentrations are 1.00 M and 0.0100 M. With n = 2, E°cell = 0 because the couples are identical. The Nernst term generates Ecell ≈ (0.0592/2) log10(1.00/0.0100) = +0.0592 V in the discharge direction. The dilute half-cell is the anode: oxidation adds M2+; reduction consumes M2+ in the concentrated cathode half-cell.
Independent Check · P05-Q3
Repair the Model
Compare what oxidation and reduction do to metal-ion concentration. Use the ratio of higher to lower activity only after choosing the favorable discharge orientation.
Fresh Transfer Case
Named battery application: In lead-acid discharge, Pb is oxidized, while PbO2 is reduced, and both electrodes form PbSO4. In NiCd discharge, cadmium is oxidized, while the oxidized nickel species is reduced. Recharging drives the net discharge chemistry in reverse using external electrical work. See the already-published worked reactions in WP10575; their quantitative stoichiometry is not replaced here.
3. Current Measures Charge, Not Guaranteed Product
For an electrolytic copper-plating cathode, Cu2+ + 2e− → Cu(s). If the measured current is 0.500 A for 3860 s, then the total charge is 1930 C. Using Faraday’s constant 96,485 C per mole electrons, that charge provides 0.0200 mol electrons, 0.0100 mol Cu, and 0.636 g Cu at a copper molar mass of 63.55 g/mol, assuming 100% current efficiency.
Guided Experiment: Compare Theoretical With Measured Mass
The table is an original synthetic teaching dataset. Copper-ion concentration, electrode identity and area, temperature, and solution composition are held constant. The cell is driven by an external source. A current sensor records average current, a stopwatch records duration, and an analytical balance measures dried cathode mass change after rinsing. The no-current control checks for deposition or weighing artifacts without passed electrical charge.
| Trial | Average current (A) | Time (s) | Charge (C) | Measured mass gain (g) |
|---|---|---|---|---|
| No-current control | 0 | 3860 | 0 | 0.000 |
| A | 0.500 | 3860 | 1930 | 0.510 |
| B | 0.500 | 1930 | 965 | 0.255 |
The ideal Faraday model predicts 0.636 g for A and 0.318 g for B. Both measured masses are approximately 80% of ideal. The data support an approximately constant apparent current efficiency in these two trials, not a unique cause of the shortfall; competing reactions, plating losses, and mass-measurement artifacts require separate controls. A battery’s anode is always the oxidation electrode, but a driven electrolytic cell’s anode is positive whereas a discharging galvanic cell’s anode is negative.
Guided Check · P05-Q4
Repair the Model
Calculate Q=IΔt, electron moles Q/F, copper moles Q/(2F), and theoretical mass. Only then form measured/theoretical and report the inference ceiling.
Fresh Transfer Case
Independent Check · P05-Q5
Repair the Model
Separate observation (mass and charge) from mechanism (which reaction used electrons or where copper mass was lost). Add a directly measuring control before assigning the mechanism.
Fresh Transfer Case
Return to This Thread
Optional Delayed Retrieval: Rebuild Your Electron Account
Explain the factor of six between moles of dichromate and iodide in the given reaction. Predict which half-cell oxidizes when two identical metal electrodes differ only in metal-ion concentration. Name one reason measured electrode mass may differ from theoretical deposited mass without changing the electron stoichiometry.
Next: Complete Magnetic Deflection and Crossed-Field Reasoning to close the remaining 4C integration block.

