Retrieval Objective
DDQX-ANKI-R2-M026-C0011
A pulse produces less depolarization than predicted from injected current and calibrated capacitance. Which concurrent current could account for the discrepancy?
Reveal Answer and Explanation
An opposing ionic or leak current.
Only the net capacitive current charges the membrane. Part of the applied current can flow through ion pathways.
T3 · Predict or localize
- From Electric Fields to Membrane Voltage · Guided Experiment: Change Pulse Duration, Not Capacitance
- Capacitors: distinguish stored charge, voltage, and energy · Capacitors Dielectrics And Stored ↔ Resting Membrane Potential