DDQX Learning Institute · MCAT Learning Thread T11
Decide Whether a Coupled Membrane Transport Step Can Run
Answer checking requires JavaScript. Worked explanations and practice prompts remain readable.
Guided, formative instruction · Not a calibrated exam or readiness assessment
What You Will Be Able to Do
- Combine chemical and electrical components with a consistent direction convention.
- Include the actual ion stoichiometry when judging whether a coupled uphill transport step is favorable.
Build the Mechanism
For moving Na+ from outside to inside, use ΔG_Na,in = RT ln([Na+]in/[Na+]out) + F(Vin − Vout). A negative value favors Na+ entry. A cotransporter that moves two Na+ inward per glucose can, in principle, use twice that favorable Na+ free-energy change to drive one uphill glucose step. A negative sum is favorable; a positive sum is not. The transport protein can still be kinetically limited.
Prerequisite and Route
Read reaction free energy, electrochemical potentials, and Na+-coupled transport first.
Work Through the Evidence
Exact worked model at 310 K: take RT = 2.58 kJ/mol, F = 96.5 kJ/(V·mol), [Na+]out = 150 mM, [Na+]in = 15 mM, Vin − Vout = −0.070 V, and +15.0 kJ/mol for uphill glucose movement. One sodium entry gives about 2.58 ln(0.1) − 6.755 = −12.7 kJ/mol. Two entries coupled to glucose give about −25.4 + 15.0 = −10.4 kJ/mol. These are explicitly supplied teaching assumptions, not a claim of a particular human cotransporter.
| Condition | Na+ stoichiometry | Membrane voltage (Vin−Vout) | Combined ΔG per glucose |
|---|---|---|---|
| Baseline | 2 inward | −70 mV | about −10.4 kJ/mol |
| Same voltage, only one Na+ | 1 inward | −70 mV | about +2.3 kJ/mol |
| Voltage collapses | 2 inward | 0 mV | about +3.1 kJ/mol |
Guided Interpretation
The molecular gradient supplies a favorable chemical term even at zero voltage, but two inward Na+ movements at zero voltage are not sufficient to offset the stipulated +15 kJ/mol glucose step. At −70 mV, two sodium movements are sufficient; one is not. This is a direction-and-stoichiometry decision, not simply a statement that sodium gradients always permit any cotransport.
Inference boundary: The chosen transporter and concentrations are synthetic. Use the specific charges, sign conventions, ion counts, and coupled solute stoichiometry supplied by any actual question. Thermodynamic favorability does not guarantee fast transport or transporter expression.
Guided Check
If Your Model Failed, Repair This Step
Sign-repair: first define movement (outside to inside), then write Vin−Vout, then multiply each ion’s ΔG by the number transported. Only then add the uphill neutral-solute cost.
Then return to the fresh transfer check. Revising a previously exposed answer is practice, not new cold evidence.
New-Case Transfer
Try this case without looking back at the guided answer. It tests a different use of the same reasoning move.
Optional Delayed Retrieval
Return after at least a day and answer in your own words before opening the model. This activity is not tracked or scored.
Reveal Model Response
More favorable coupled ΔG changes direction feasibility, while actual rate also depends on transporter number, turnover, substrate availability, and other kinetic constraints.
Continue Learning
Return to the canonical lessons for complete topic instruction and worked examples. This activity adds integration and transfer, not a replacement textbook.
Source Basis and Limits
The synthetic measurements above were authored for formative practice. Official AAMC content outlines define topical scope; sources below support the mechanisms but do not authenticate the invented data or establish exam equivalence.
- https://students-residents.aamc.org/biological-and-biochemical-foundations-living-systems-foundational-concept-1/biological-and-biochemical-foundations-living-systems-content-category-1d
- https://students-residents.aamc.org/biological-and-biochemical-foundations-living-systems-foundational-concept-3/biological-and-biochemical-foundations-living-systems-content-category-3a
Formative teaching only. This activity is not a calibrated MCAT assessment or a score prediction.