Answer checking requires JavaScript. You can still read the lesson, figures, and questions.
DDQX Learning Institute
Account for Energy Across Thermodynamic Paths
System boundaries, calibrated heat, cyclic work, reaction energy, and phases
Choose a system and an energy equation, retain units and path information, and distinguish energy availability from reaction speed.
Objectives and Starting Point
What You Will Be Able to Do
- Balance heat uptake by sample, water, and calorimeter.
- Calculate the sign and magnitude of work over a complete pressure-volume loop.
- Use Hess directionality and temperature-dependent free energy correctly.
- Transfer thermal expansion and phase-change models without mixing their units.
- Separate standard-state favorability from the actual free-energy drive of a mixture.
Choose Your Starting Point
Review the system boundary and calorimeter before solving. The closed-cycle and thermal-expansion tasks are targeted new transfer checks, not replacements for the active practice in the canonical lessons.
Open the Canonical Lesson Path
- Heat and temperature: interpret a calorimetry measurement WP10709
- The first law: account for heat, work, and internal energy WP20811
- Reaction enthalpy: combine Hess cycles and bond-energy estimates WP10710
- Entropy and temperature: explain when a process is favored WP10711
- Free energy and equilibrium: distinguish standard from actual conditions WP10712
- Phase changes: read heating curves and pressure–temperature diagrams WP20813
DDQX 5P Approach: Prioritize, Paraphrase, Prognose, Pick, and Post-Mortem.
Include the Apparatus in Heat Accounting
Apply: An original insulated-cup teaching model places a 100-g solid at 80 C into 200 g of water initially at 20 C. The water and calorimeter start at 20 C and end at 25 C. Use c_water = 4.2 J/(g K), calorimeter heat capacity C_cal = 100 J/K, and neglect external loss only for this stipulated calculation.
Reveal Worked Reasoning
- The water gains q_w = (200 g)(4.2 J/(g K))(5 K) = +4200 J.
- The calorimeter gains q_cal = (100 J/K)(5 K) = +500 J. The solid therefore loses 4700 J in the insulated model.
- The solid cools 55 K, so c_solid = 4700 J/[(100 g)(55 K)] = approximately 0.855 J/(g K). In a real setup, late temperature drift or heat leakage needs measurement and correction.
Conclusion: The calorimeter is another energy reservoir; omit it and the inferred solid heat capacity will be biased downward in this example.
Fresh Transfer
A different condition or representation tests the same operation.
Next: Use the original lesson temperature trace when deciding whether external heat loss can be ignored.
Canonical evidence path: WP10709
Close the Pressure-Volume Loop
Apply: A stipulated clockwise rectangle on a P-V diagram has two horizontal legs: expansion from 1 to 3 L at 200 kPa and compression from 3 to 1 L at 100 kPa. The other legs are constant-volume pressure changes. One kPa L equals one joule.
Reveal Worked Reasoning
- During expansion, work done by the gas is +(200 kPa)(2 L)=+400 J.
- During compression, work done by the gas is (100 kPa)(-2 L)=-200 J. Isochoric legs contribute zero pressure-volume work.
- The complete loop gives W_by = +200 J and w_on = -200 J. The cycle returns to its initial thermodynamic state so delta U_cycle = 0 and q_cycle = +200 J using delta U=q+w_on.
Conclusion: For a complete closed loop, the enclosed signed area is net P-V work; the internal-energy state change is zero, not the net heat or work.
Fresh Transfer
A different condition or representation tests the same operation.
Next: This closed-loop extension is distinct from the existing canonical two-path example.
Canonical evidence path: WP20811
Reverse the Reaction Before Adding Its Enthalpy
Apply: A classroom Hess cycle specifies A -> B with delta H = +60 kJ/mol and B -> C with delta H = -15 kJ/mol, where all states and stoichiometric bases are compatible.
Reveal Worked Reasoning
- Enthalpy is a state function for the stipulated thermochemical states.
- Add forward reactions A -> B and B -> C; B cancels, yielding A -> C with delta H = +45 kJ/mol.
- If the required target were C -> A, reverse the entire net equation and the enthalpy sign to -45 kJ/mol. Multiplying a thermochemical equation multiplies delta H by the same factor.
Conclusion: Write the target stoichiometry, reverse and scale available steps, then cancel chemical species and add enthalpies.
Fresh Transfer
A different condition or representation tests the same operation.
Next: Use the standard formation-enthalpy or bond-energy lessons to identify what each model can and cannot estimate.
Canonical evidence path: WP10710
Choose the Temperature Before Calling a Process Favored
Apply: A hypothetical reaction under standard-state convention has delta H = +30 kJ/mol and delta S = +100 J/(mol K), treated constant over the temperature interval for this exercise.
Reveal Worked Reasoning
- Convert entropy units: +100 J/(mol K) = +0.100 kJ/(mol K).
- At 350 K, delta G_standard = 30 – (350)(0.100) = -5 kJ/mol. At 250 K, it is +5 kJ/mol, giving a crossover at 300 K in the simplified model.
- For a nonstandard mixture, actual delta G_reaction = delta G_standard + RT ln Q. A negative standard value is not sufficient to determine the actual direction without composition.
Conclusion: Distinguish a temperature-dependent standard free energy from the actual reaction driving force at a specified Q.
Fresh Transfer
A different condition or representation tests the same operation.
Next: Use the Free Energy and Equilibrium page before the kinetics thread to keep K/Q separate from barriers.
Keep Thermal Expansion Separate From Phase Heat
Apply: An unconstrained rod is 2.0 m long and has constant linear expansion coefficient alpha = 1.2 x 10^-5 K^-1 over a modest 50-K rise. Separately, a 50-g solid at its melting point has latent heat of fusion 334 J/g.
Reveal Worked Reasoning
- For the rod, delta L = alpha L0 delta T = (1.2 x 10^-5 K^-1)(2.0 m)(50 K)=0.0012 m=1.2 mm.
- For a phase change at constant temperature, q_fusion = m L_f = (50 g)(334 J/g)=16,700 J.
- Do not apply q=mc delta T to a melting plateau, or convert a thermal length change into an energy. Both formula choices depend on the process conditions.
Conclusion: A linear expansion measurement and a latent-heat requirement quantify different physical outcomes with different dimensions.
Fresh Transfer
A different condition or representation tests the same operation.
Next: This pair supplies the workbook's specifically flagged closed-loop and numerical-expansion transfers without replacing existing canonical examples.
Optional Delayed Retrieval
Revisit these prompts later using a fresh sheet or note. They do not silently alter any DDQX Study Planner schedule.
- Recompute the same calorimetry problem with a nonzero calorimeter heat capacity.
- Reverse the direction of the P-V cycle and state the effect on w_on and q_cycle.
- Explain why a reaction can have delta G_standard < 0 yet actual delta G_reaction > 0.
Exit and Next Route
Advance when the selected model, boundary, sign, and units remain correct on unseen numbers. Do not interpret this formative result as an MCAT readiness classification.
Related Guided Modules
These are original hypothetical teaching examples and formative checks. They are not results from a primary study, independently accepted MCAT items, calibrated difficulty measures, readiness predictions, or calibrated assessment evidence. The official AAMC category and canonical DDQX lesson references support topic alignment only.