MCAT content library / Biology & biochemistry / The cardiac cycle and circulation
Connect four-chamber anatomy, valve pressure differences and volume conservation to explain how blood circulates.
About 17 minutes, including the worked examples and checks.
Useful foundations
On this page
- Trace a complete circuit before interpreting a pressure
- Concept: a valve follows its local pressure difference
- Worked application: infer valve states from snapshots
- Calculate output without counting the same blood twice
- Pattern: vessel structure changes pressure and velocity
- Application: distinguish pumping from resistance
- Check your reasoning
- Continue learning
- Sources
Trace a complete circuit before interpreting a pressure
A useful circulation model has two pumps arranged in series. The right heart supplies the pulmonary circuit; the left heart supplies the systemic circuit. Each pump generates pressure, and valves favor forward flow. The AAMC asks you to connect this anatomy with pressure, vascular properties and physiological regulation.1
Blood returning from systemic tissues enters the right atrium, crosses the tricuspid valve into the right ventricle, and leaves through the pulmonary valve toward the lungs. It returns through pulmonary veins to the left atrium, crosses the mitral valve into the left ventricle, and exits through the aortic valve into the systemic circulation. A septum separates the right and left sides.2
An artery carries blood away from the heart; a vein returns it. These names describe direction, so pulmonary arteries can carry blood with less oxygen than pulmonary veins. The left ventricle normally generates a greater pressure than the right because the systemic circuit presents greater resistance. Greater pressure does not mean that its sustained volume output can simply exceed the other pump’s output.25
Concept: a valve follows its local pressure difference
For an ideal valve with negligible opening threshold, forward upstream pressure opens it; a reversed pressure difference closes it. The myocardium creates the changing pressures. The valve itself does not actively propel blood. The atrioventricular valves connect atria to ventricles, whereas the semilunar valves connect ventricles to their outflow arteries.3
Systole means contraction, and diastole means relaxation; specify the chamber because atria and ventricles do not contract simultaneously. During ventricular filling, an atrioventricular valve is open. After ventricular pressure rises above atrial pressure but before it exceeds outflow-artery pressure, both valves are closed: isovolumetric contraction. Ejection follows when the outflow valve opens. Early relaxation again closes both valves until ventricular pressure falls below atrial pressure.3
Worked application: infer valve states from snapshots
Consider an original ideal left-heart model. The mitral valve permits left atrium-to-ventricle flow; the aortic valve permits ventricle-to-aorta flow. Assume no leak, shunt or opening delay. Pressures share one reference. The values are separate snapshots within the named phases, not a full measured pressure waveform or equal-duration time intervals.
| Phase | Left atrium | Left ventricle | Aorta |
|---|---|---|---|
| Filling | 8 | 5 | 75 |
| Isovolumetric contraction | 8 | 40 | 80 |
| Ejection | 8 | 110 | 95 |
| Isovolumetric relaxation | 8 | 30 | 85 |
During filling, 8 > 5 opens the mitral valve, but 5 < 75 keeps the aortic valve closed. During ejection, 110 > 95 opens the aortic valve, while 110 > 8 closes the mitral valve against backward flow. Both valves are closed in each isovolumetric snapshot, even though one occurs during contraction and the other during relaxation.
The rule therefore identifies valve state from pressures, but a single both-closed snapshot does not tell you whether ventricular pressure is rising or falling. That requires the time sequence or another measurement. Likewise, a closed aortic valve does not mean all systemic blood flow stops: stretched arterial walls can recoil between ventricular ejections.6
Calculate output without counting the same blood twice
Stroke volume is the amount ejected by one ventricle per beat: SV = end-diastolic volume − end-systolic volume. Cardiac output is its volume per unit time: CO = heart rate × SV. Heart rate alone is insufficient because filling and the volume ejected per beat can also change.4
For an original example, end-diastolic volume is 120 mL and end-systolic volume is 45 mL. Thus SV = 75 mL/beat. At 72 beats/min, CO = 72 × 75 = 5400 mL/min, or 5.4 L/min. If rate rises to 90 beats/min while SV falls to 60 mL/beat, output remains 5.4 L/min. A faster rate has not increased volume delivery in that supplied case.
In a steady, closed, ideal circuit without shunts or fluid accumulation, average right- and left-ventricular outputs must match. Adding two 5.4 L/min outputs to claim 10.8 L/min systemic delivery counts the same circulating stream twice. If inflow to a compartment temporarily exceeds outflow, its volume increases by the difference multiplied by elapsed time. This conservation argument explains why a persistent mismatch cannot describe an unchanged steady state.
Pattern: vessel structure changes pressure and velocity
Large elastic arteries stretch with ejection and recoil afterward. Muscular arteries distribute flow, and arterioles adjust resistance through smooth-muscle contraction. Capillaries provide thin exchange surfaces; venules collect their output, and veins return blood while accommodating substantial volume at relatively low pressure. Venous valves and surrounding muscle activity can support return without supplying a second ventricular pump.5
Pressure falls as blood moves through a resistive circuit; a substantial systemic drop occurs across arterioles. The large combined cross-sectional area of parallel capillaries permits relatively low blood velocity. Do not confuse a single tiny capillary’s resistance with the effective resistance of the entire capillary network, or blood speed with the total volume passing through all branches per minute.6
Application: distinguish pumping from resistance
For a defined circuit, use time-averaged values in Q = ΔP/R. The relevant ΔP is inlet pressure minus outlet pressure, not automatically the arterial pressure alone. If Q is 5.4 L/min and ΔP is 90 mmHg, effective R is 90/5.4 = 16.7 mmHg·min/L. At the same measured flow, a rise to 108 mmHg gives R = 20.0: a 20% increase. These values describe the model’s effective resistance, not a diagnosis.
Sympathetic activity can increase cardiac rate and contractile force, while parasympathetic activity prominently slows the heart. Circulating catecholamines can affect both heart and vessels; the vascular result depends on receptors and tissue. Other hormonal pathways influence blood volume or vascular tone, and local tissue signals redistribute flow. Therefore, predict a final pressure only after identifying which quantities are actually held constant or measured.47
For a new passage, trace the route, compare pressures across each valve, calculate flow with units, and check whether the proposed behavior conserves volume. These steps connect anatomy to a testable physical model without requiring a detailed clinical waveform.
ACTIVE PRACTICE · INTERPRETATION AND TRANSFER
Infer Valve States From Local Pressure Differences
The original ideal left-heart snapshots report left atrial (LA), left ventricular (LV), and aortic pressures in mmHg. Valves are ideal and instantaneous; these rows are separate phases, not equal-duration time samples.
Inspect the reasoning boundary
Interpret the measured quantities and explicit assumptions; an instructional check is not a validated performance score.
Check your reasoning
Choose an answer before opening its feedback. Each option explains the reasoning behind that choice.
Check 1
In an ideal left heart with competent valves and negligible opening thresholds, left atrial pressure is 9 mmHg, left ventricular pressure is 12 mmHg and aortic pressure is 80 mmHg. Which valve state follows from this single snapshot?
A. Both the mitral and aortic valves are closed.
Correct. Ventricular pressure exceeds atrial pressure, closing the mitral valve, but remains below aortic pressure, keeping the aortic valve closed.
B. Both the mitral and aortic valves are open.
Review this choice. Neither forward pressure condition is met: atrial pressure is too low to open the mitral valve, and ventricular pressure is too low to open the aortic valve.
C. The aortic valve is open and the mitral valve is closed.
Review this choice. The mitral state is correct, but 12 mmHg cannot open the aortic valve against 80 mmHg in this model.
D. The mitral valve is open and the aortic valve is closed.
Review this choice. The aortic state is correct, but the ventricle is at higher pressure than the atrium, so the mitral valve is closed.
The principle to carry forward
A both-closed state can occur during contraction or relaxation; pressure trend is needed to distinguish those phases.
Check 2
A closed-loop experimental model has no shunts, leaks or fluid exchange. Define a compartment from just after the right-ventricular outflow to just before the left-ventricular outflow. For 30 seconds its measured inflow is 5.8 L/min and outflow is 5.0 L/min. What happens to the volume within that compartment over the interval?
A. It decreases by 0.4 L.
Review this choice. Inflow exceeds outflow, so the compartment gains rather than loses volume.
B. It increases by 0.4 L.
Correct. Net accumulation is (5.8 − 5.0) L/min × 0.5 min = 0.4 L.
C. It increases by 0.8 L.
Review this choice. The net rate is 0.8 L/min, but it acts for only half a minute.
D. It remains unchanged because the two pumps are in series.
Review this choice. Series arrangement requires equal average flows in a steady state. The supplied transient mismatch means this compartment is not in an unchanged steady state.
The principle to carry forward
State the compartment boundary and multiply net flow by time; conservation also detects an inconsistent steady-state claim.
Check 3
In a steady ideal systemic circuit, baseline heart rate is 80 beats/min, stroke volume 75 mL/beat, mean arterial pressure 98 mmHg and right atrial pressure 2 mmHg. After an intervention, the values are 100 beats/min, 60 mL/beat, 122 mmHg and 2 mmHg. Use Q = ΔP/R. Which comparison is correct?
A. Flow increases by 25%; effective resistance is unchanged.
Review this choice. Heart rate rises by 25%, but the smaller stroke volume offsets that increase. Both outputs are 6.0 L/min.
B. Flow is unchanged; effective resistance increases by 25%.
Correct. Q is 6.0 L/min in both states. Baseline R = (98 − 2)/6 = 16; afterward R = (122 − 2)/6 = 20 mmHg·min/L, a 25% rise.
C. Flow is unchanged; effective resistance decreases by 20%.
Review this choice. The pressure difference rises at the same flow, so resistance rises. The baseline-to-final ratio cannot be substituted for the percent increase from baseline.
D. Flow decreases by 20%; effective resistance increases by 25%.
Review this choice. Stroke volume falls by 20%, but heart rate also changes. Multiplying the two quantities gives an unchanged output.
The principle to carry forward
Compute output and the complete pressure difference before inferring a change in resistance.
Continue learning
Browse biology & biochemistry · MCAT content library
MCAT preparation and roadmap · Aim High, Score Higher
Sources
1. AAMC — B/B Content Category 3B
2. OpenStax Anatomy and Physiology 2e — 19.1 Heart Anatomy
3. OpenStax Anatomy and Physiology 2e — 19.3 Cardiac Cycle
4. OpenStax Anatomy and Physiology 2e — 19.4 Cardiac Physiology
5. OpenStax Anatomy and Physiology 2e — 20.1 Structure and Function of Blood Vessels
6. OpenStax Anatomy and Physiology 2e — 20.2 Blood Flow, Blood Pressure, and Resistance
7. OpenStax Anatomy and Physiology 2e — 20.4 Homeostatic Regulation of the Vascular System
