Retrieval Objective
DDQX-LEARN-CECBBB2F398EDFC8
Why can an atrial septal defect cause a persistently wide split second heart sound with little respiratory variation?
Reveal Answer and Explanation
The interatrial shunt buffers respiratory changes in right-ventricular filling and pulmonary-valve closure timing.
Right-heart flow is increased and normal inspiratory-versus-expiratory changes in the A2-P2 interval are reduced, creating the classic fixed split S2.
Original source: Quiz of the Day — Pediatrics — Congenital Heart Disease Mixed Review — Part 4 — collection hub. An edition-specific or unpublished source URL is not represented as verified.