Treated matrix and water start at the same analyte concentration. The same concentration spike yields a smaller baseline-subtracted optical increment in the matrix. What assumption fails over this tested interval?
Reveal Answer and Explanation
That the water calibration gives the same signal change per concentration increment in the matrix.
The matched starts and spikes isolate the response difference for that increment. The result cannot establish how the matrix responds over the entire curve.
T4 · Evaluate evidence
- Reading a multi-figure experiment from claim to conclusion · Rule: test an assay explanation before treating it as biology
- From a Dataset to a Supported Claim · Panel B — Optical Endpoint and Matrix Check