MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

An ultrasound echo takes 80 µs to return along a homogeneous path with c = 1500 m/s. What one-way depth does that delay imply?

DDQX-ANKI-R2-M042-C0001

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

The instrument assumes a sound speed that is too high for the tissue. How does that bias depth estimated from a given round-trip delay?

DDQX-ANKI-R2-M042-C0002

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

Two reflectors return echoes with identical delays through the same homogeneous medium but different frequency shifts. Which measured property must match under the pulse-echo model?

DDQX-ANKI-R2-M042-C0003

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

In one homogeneous medium, the transmitted ultrasound frequency is doubled. What happens to its wavelength?

DDQX-ANKI-R2-M042-C0004

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T1

Why does the small-speed reflected Doppler shift contain a factor of two?

DDQX-ANKI-R2-M042-C0005

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

With positive shift defined for approach, what sign does blood moving directly away from the ultrasound transducer produce?

DDQX-ANKI-R2-M042-C0006

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

Why can a flowing vessel return almost no Doppler frequency shift when scanned perpendicular to its axis?

DDQX-ANKI-R2-M042-C0007

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

The same flow is insonated at 60° instead of parallel to its velocity. With all else fixed, what happens to the magnitude of the reflected Doppler shift?

DDQX-ANKI-R2-M042-C0008

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

A reflected signal shifts by 800 Hz for a 4 MHz beam in tissue with c = 1600 m/s. What is the magnitude of the axial velocity component?

DDQX-ANKI-R2-M042-C0009

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

Why is speed inferred by Doppler angle correction especially uncertain near 90°?

DDQX-ANKI-R2-M042-C0010

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T4

A Doppler measurement gives one centerline speed in a vessel of known diameter. Why may multiplying that speed by area overestimate flow?

DDQX-ANKI-R2-M042-C0011

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

A circular vessel has 0.50 cm² cross-sectional area and 12 cm/s mean velocity normal to the section. What is its volume flow rate?

DDQX-ANKI-R2-M042-C0012

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

Two echoes traverse the same homogeneous material. One reflector is 1.5 cm deeper than the other; c = 1500 m/s. How much later does its echo arrive?

DDQX-ANKI-R2-M042-C0013

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T2

The transmitted frequency doubles while reflector velocity, beam angle and sound speed stay fixed. What happens to the reflected frequency shift in the small-speed approximation?

DDQX-ANKI-R2-M042-C0014

Open card details

MCAT · MOD-042 · Doppler Ultrasound: Locate and Measure · T3

Doppler-derived cross-sectional mean speed doubles while the circular vessel diameter halves. How does volumetric flow change?

DDQX-ANKI-R2-M042-C0015

Open card details

For corrections, use the existing DDQX website issue reporter and include the CardID. Source-specific QOTD edition links are not assumed where still unresolved.